VENTANA©2015, Miles Industries Ltd. All rights reserved.4001272-30Direct Vent ZC Fireplace1200EAN (NG) & 1200EAP (LPG)Installation & Owner’s M
10ONOFFManual ON/OFF SwitchHow to Ensure Your Fireplace Cannot Be Turned ON InadvertentlyYou can use one of the two following methods to ensure that y
11Remote Control OperationWhen the pilot is off, it will take 2 minutes before it can be lit again.TO TURN ON APPLIANCE TO TURN OFF APPLIANCEFLAME HEI
12Remote Control OperationSETTING THE TIMESETTING ºC/24-HOUR OR ºF/12-HOUR CLOCKMODES OF OPERATIONNOTE: Manual mode can also be reached by pressing ei
13Remote Control OperationSETTING THE ON / OFF TEMPERATURES• Briefl y press SET button to scroll to TEMP (sun) mode. Hold the SET butt
14SETTING PROGRAM TIMERS• You can program two periods of time between 12:00 am and 11:50 pm in each 24-hour cycle.• The Programs P1 and P2 must be s
15Remote Control OperationOptionsRequired Kits*Ceramic Liners1245VRL—Victorian Red Liner Pack1250FSL—Frontera Liner Pack1255IBL—Inca Slab Liner Pack12
16Lighting InstructionsWARNING: If you do not follow these instructions exactlyD¿UHRUH[SORVLRQPD\UHVXOWFDXVLQJSURSHUW\GDPDJHSHUVRQDOLQMXU
17State of Massachusetts Carbon Monoxide Detector/Vent Terminal Signage RequirementsFor all side wall horizontally vented gas fueled equipment install
18(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved side wall horizontally vented
19RatingsModel N PGasNatural PropaneAltitude (Ft.)*0-4,500 feet*Input Maximum (Btu/h)36,000 31,000Input Minimum (Btu/h)15,000 15,000Manifold Pressure
Safety Precautions ... 3Safety and Your Fireplace ...4Owner’s Informa
20OverviewFire On/Off Wall Switch (optional)Mantel—See Mantel ClearancesNon-combustible Hearth—See Hearth RequirementsDecorative Light Dimmer Switch(n
21DimensionsLocation18”43”32-1/2”33””28”24”7-1/8”8-1/2”51-1/2” to top of cement board50” to underside of headerElectrical(for ambientlight only)Elec
22Combustible Mantel—Left Side ViewMantel ClearancesBottom of UnitFace of Cement Board0 2” 4” 6” 8” 10” 12”50”45”43”41”39”36”33”28”Mantel Projection(f
232” 1”4”5” 3”2”1”4”5”3”32-1/2”Fireplace OpeningWallMin. 6” between edge of openingand wallFace of FinishedWallNoteRight Side Clearances are the same
24Hearth RequirementsGeneral Hearth ConsiderationsTop of Finished Hearth Must Be Flush With Bottom of Heater to accommodate some optional mantels and
25Hearth RequirementsUnit Raised Above Combustible Hearth or FloorFace of Cement BoardTop Face of Combustible Floor or Carpet4” MIN.Base of FireplaceC
26Unit With Site-Built Non-Combustible Hearth ExtendingUsing 616/617STK Stone Trim KitsFront of Fireplace(Surface of Cement Board)Min. Hearth Projecti
27Framing24”50”43-1/2”1/2” thick cement board required above and on each side of engine(supplied w/engine) - Combustible wall finish may butt up to bu
28VentingVent MaterialThis unit is approved for installation using 4 x 6-5/8 inches co-axial direct vent pipe and accessories as listed in the Approve
29Co-axial VentingHORIZONTALTERMINATION2-PIECEWALLTHIMBLEPIPELENGTHPIPELENGTHPIPELENGTHPIPELENGTH90˚ ELBOWCEILINGFIRESTOPATTICFIRESTOPATTICINSULATIONS
3Safety Precautions!Children and adults should be ALERTED to the hazards of high surface temperature and should STAY AWAY to avoid burns or clothing i
30How to Read the Venting ChartThe chart below applies to roof or wall termination.1. The total length of the vent pipe cannot exceed 40 feet (12.2 m
31RestrictorMANY INSTALLATIONS REQUIRE A RESTRICTOR for improved fl ame picture and performance, This unit is supplied with one restrictor having four
32Vent Termination• The vent terminal must be located on an outside wall or through the roof.• This direct vent appliance is designed to operate whe
Ventanaengine33Flashing2 x 3”liners3” min.bend radiusCo-linearadapter2 x 3”linersCo-linearadapterVogueengineApproved co-linear termination or approved
34Installation PlanningInstaller—READ THIS FIRST1. Unpack the appliance.2. Check that you have everything.3. Finish framing.4. Fit appliance into f
35InstallationUnpack the applianceTo assist you, we have included the cement and hearth insulation boards required in the installation. The boards nee
36InstallationFix the appliance to the fl oor1. Remove the front bottom overlay panel and the barrier screen lower brackets by removing 1 screw on eac
37InstallationRemove WindowThe window is held in place by a spring-loaded lever on each side. 1. To remove the window, locate the levers on each side
38The unit is supplied with a stainless steel fl ex line to allow the appliance to be disconnected for service. The fl ex line is supplied loose to avoi
39Install LinersThe following guidelines apply for all brick liners.1. Inside the fi rebox, on the top of each side, release the screw of the side bric
4Safety and Your FireplacePlease Follow These Important Child Safety Precautions and Recommendations,• Parts of your Valor Fireplace become extremel
40Install Ceramic LogsThe ceramic logs are supplied in two packages. Unpack them very carefully to avoid damaging the fragile material. Install the lo
417. Place the Top Right Log on the right pin of the rear log with its narrow end resting on the middle and the middle right logs.6. Place the Top L
422. While you hold it, pull the side levers back into the window brackets on each side.3. Pull out the top of the window and release it to insure t
43Install Electrical Components for Decorative LightingWall Dimmer SwitchThe electrical installation must be performed by a qualifi ed installer and mu
44Air Shutter inOpen PositionAir Shutter inClosed PositionAir ShutterCheck OperationTurn the fi replace fl ame up and down using the remote control to c
45Install Handset Wall HolderThe remote control kit for this fi replace comes complete with a wall-mounted holder. This holder is not required in all i
46Wiring DiagramOptional Wall Switch Kit 1265WSKConnectorRedYellowGV60 Wiring DiagramQUALIFIED INSTALLER
47Approved Venting ComponentsApproved Direct Vent Suppliers for Valor Models 1100, 1150, 12005, 1500, 16005 and 17006Venting Parts Description Venting
48Approved Venting Components Venting Parts DescriptionVenting Parts Code / availability by ManufacturerDURA-VENTSELKIRKICC EXCEL DIRECTSECURE VENT RL
49Warranty1. Extended Warranty CoverageFor a period of up to ten (10) years, Miles Industries Ltd., (the “Company”) or its appointed distributor will
5Operating Your Fireplace for the First TimeWhen operating your new fi replace for the fi rst time, some vapors may be released due to the burning of cu
50Code DescriptionPart Number1 Intake Collar 40009252 Intake Collar Gasket 40009423 Top Standoff (2) 40013734 Firebox5 Air Inlet Duct Assembly 4001246
51Spare PartsCode DescriptionPart Number67 Rear Panela Victorian Red Brick 4001226b Frontera Stone 4001321c Inca Slab 4001322d Black Slab 400148068 RH
123456789101112131415161774757776171811565563697219a,19bPilot Assy 20a to 2728a, 28b31a, 31b33Module Plate Gaskets 34 to 3739404242a435960616238a, 38b
Thank You ...For purchasing a Valor by Miles Industries. Your new radiant gas heater is a technical appliance that must be installed by a qualifi ed in
Tape ShutThank you for choosing a Valor ProductPostageneededWere you given all documentation and manuals for your product? YES NOMiles Industries Lt
6Cleaning Your FireplaceImportant - Glass cleaning - Mineral depositsOne of the by-products of the combustion process in a gas appliance is a mineral
7IMPORTANT: To ensure a safe operation, ensure that the spring-loaded mechanism functions properly.Hot Glass Warning PlateTo refi t the window:1. Plac
8Owner’s InformationCAUTIONDO NOT USE a screwdriver or other metallic object to remove the batteries from the receiver or the handset! This could caus
9Owner’s InformationLocating Lighting, Operation and Rating Information PlateThe Lighting, Operation and Rating information is located on a plate at t